EDI COSTCOContainer stuffing stripping confirmation message

Transaction set

This specification provides the definition of the container stuffing/stripping confirmation message (costco) to be used in electronic data interchange (edi) between trading partners involved in administration, commerce and transport.

Segments

Position
Segment
Name
Max use
10
UNH
Message header
To end and check the completeness of an interchange
Mandatory
AtMax 1
20
BGM
Beginning of message
To indicate the type and function of a message and to transmit the identifying number.
Mandatory
AtMax 1
30
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
40
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
1LOOPOpt
AtMax 9
60
RFF
Reference
To specify a reference.
Mandatory
AtMax 1
70
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
2LOOPMandatory
AtMax 1
90
TDT
Details of transport
To specify the transport details such as mode of transport, means of transport, its conveyance reference number and the identification of the means of transport. the segment may be pointed to by the tpl segment.
Mandatory
AtMax 1
100
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
3LOOPOpt
AtMax 9
120
LOC
Place/location identification
To identify a place or a location and/or related locations.
Mandatory
AtMax 1
130
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
4LOOPMandatory
AtMax 9
150
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Mandatory
AtMax 1
5LOOPOpt
AtMax 9
170
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
180
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
6LOOPMandatory
AtMax 999
200
EQD
Equipment details
To identify a unit of equipment.
Mandatory
AtMax 1
210
RFF
Reference
To specify a reference.
Opt
AtMax 9
220
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
230
TSR
Transport service requirements
To specify the contract and carriage conditions and service and priority requirements for the transport.
Opt
AtMax 9
240
DIM
Dimensions
To specify dimensions.
Opt
AtMax 9
250
SEL
Seal number
To specify the seal number or a range of seal numbers.
Opt
AtMax 9
260
EQA
Attached equipment
To specify attached or related equipment.
Opt
AtMax 9
270
HAN
Handling instructions
To specify handling and where necessary, notify hazards.
Opt
AtMax 9
280
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Opt
AtMax 9
7LOOPOpt
AtMax 99
300
DGS
Dangerous goods
To identify dangerous goods.
Mandatory
AtMax 1
310
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
320
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
8LOOPOpt
AtMax 9
340
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
350
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
9LOOPOpt
AtMax 9
370
TMP
Temperature
To specify the temperature setting.
Mandatory
AtMax 1
380
RNG
Range details
To identify a range.
Opt
AtMax 1
10LOOPMandatory
AtMax 999
400
CNI
Consignment information
To identify one consignment.
Mandatory
AtMax 1
410
RFF
Reference
To specify a reference.
Opt
AtMax 9
11LOOPOpt
AtMax 999
430
GID
Goods item details
To indicate totals of a goods item.
Mandatory
AtMax 1
440
HAN
Handling instructions
To specify handling and where necessary, notify hazards.
Opt
AtMax 9
12LOOPOpt
AtMax 9
460
TMP
Temperature
To specify the temperature setting.
Mandatory
AtMax 1
470
RNG
Range details
To identify a range.
Opt
AtMax 1
480
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
490
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
500
PCI
Package identification
To specify markings and labels on individual packages or physical units.
Opt
AtMax 9
510
DOC
Document/message details
To identify documents and details directly related to it.
Opt
AtMax 9
13LOOPMandatory
AtMax 999
530
SGP
Split goods placement
To specify the placement of goods in relation to equipment.
Mandatory
AtMax 1
540
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
14LOOPOpt
AtMax 99
560
DGS
Dangerous goods
To identify dangerous goods.
Mandatory
AtMax 1
570
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
580
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
15LOOPOpt
AtMax 9
600
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
610
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
16LOOPOpt
AtMax 999
630
SGP
Split goods placement
To specify the placement of goods in relation to equipment.
Mandatory
AtMax 1
640
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
650
CNT
Control total
To provide control total.
Opt
AtMax 1
660
UNT
Message trailer
To end and check the completeness of a message.
Mandatory
AtMax 1

Elements

PositionElementNameRequirementTypeMin/MaxRepeat
10
Message reference numberMandatoryAlphanumeric1/1AtMax 1
20
Message identifierMandatoryAtMax 1
10
Message type identifierMandatoryAlphanumeric1/1Exact 1
20
Message type version numberMandatoryAlphanumeric1/1Exact 1
30
Message type release numberMandatoryAlphanumeric1/1Exact 1
40
Controlling agencyMandatoryAlphanumeric1/1Exact 1
50
Association assigned codeOptAlphanumeric1/1Exact 1
30
Common access referenceOptAlphanumeric1/1AtMax 1
40
Status of the transferOptAtMax 1