EDI MOVINSStowage instruction message

Transaction set

This specification provides the definition of the stowage instruction message (movins) to be used in electronic data interchange (edi) between trading partners involved in administration, commerce and transport.

Segments

Position
Segment
Name
Max use
10
UNH
Message header
To end and check the completeness of an interchange
Mandatory
AtMax 1
20
BGM
Beginning of message
To indicate the type and function of a message and to transmit the identifying number.
Mandatory
AtMax 1
30
DTM
Date/time/period
To specify date, and/or time, or period.
Mandatory
AtMax 1
1LOOPOpt
AtMax 9
50
RFF
Reference
To specify a reference.
Mandatory
AtMax 1
60
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
70
NAD
Name and address
To specify the name/address and their related function, either by co82 only and/or unstructured by co58 or structured by co80 thru 3207.
Opt
AtMax 3
2LOOPMandatory
AtMax 3
90
TDT
Details of transport
To specify the transport details such as mode of transport, means of transport, its conveyance reference number and the identification of the means of transport. the segment may be pointed to by the tpl segment.
Mandatory
AtMax 1
100
LOC
Place/location identification
To identify a country/place/location/related location one/related location two.
Mandatory
AtMax 1
110
DTM
Date/time/period
To specify date, and/or time, or period.
Mandatory
AtMax 99
120
RFF
Reference
To specify a reference.
Opt
AtMax 1
130
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 1
3LOOPMandatory
AtMax 9999
150
HAN
Handling instructions
To specify handling and where necessary, notify hazards.
Mandatory
AtMax 1
4LOOPMandatory
AtMax 9999
170
LOC
Place/location identification
To identify a country/place/location/related location one/related location two.
Mandatory
AtMax 1
180
RFF
Reference
To specify a reference.
Mandatory
AtMax 99
190
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
200
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
210
DIM
Dimensions
To specify dimensions.
Opt
AtMax 9
220
LOC
Place/location identification
To identify a country/place/location/related location one/related location two.
Opt
AtMax 9
230
NAD
Name and address
To specify the name/address and their related function, either by co82 only and/or unstructured by co58 or structured by co80 thru 3207.
Mandatory
AtMax 99
5LOOPOpt
AtMax 1
250
TMP
Temperature
To specify the temperature setting.
Mandatory
AtMax 1
260
RNG
Range details
To identify a range.
Opt
AtMax 1
6LOOPOpt
AtMax 99
280
EQD
Equipment details
To identify a unit of equipment.
Mandatory
AtMax 1
290
EQN
Number of units
To specify the number of units.
Opt
AtMax 1
7LOOPOpt
AtMax 99
310
EQA
Attached equipment
To specify attached or related equipment.
Mandatory
AtMax 1
320
EQN
Number of units
To specify the number of units.
Opt
AtMax 1
8LOOPOpt
AtMax 9999
340
GID
Goods item details
To indicate totals of a goods item.
Mandatory
AtMax 1
350
GDS
Nature of cargo
To indicate the type of cargo as a general classification.
Opt
AtMax 1
9LOOPOpt
AtMax 999
370
RFF
Reference
To specify a reference.
Mandatory
AtMax 1
10LOOPMandatory
AtMax 99
390
DGS
Dangerous goods
To identify dangerous goods.
Mandatory
AtMax 1
400
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 1
410
UNT
Message trailer
To end and check the completeness of a message.
Mandatory
AtMax 1

Elements

PositionElementNameRequirementTypeMin/MaxRepeat
10
Message reference numberMandatoryAlphanumeric1/1AtMax 1
20
Message identifierMandatoryAtMax 1
10
Message type identifierMandatoryAlphanumeric1/1Exact 1
20
Message type version numberMandatoryAlphanumeric1/1Exact 1
30
Message type release numberMandatoryAlphanumeric1/1Exact 1
40
Controlling agencyMandatoryAlphanumeric1/1Exact 1
50
Association assigned codeOptAlphanumeric1/1Exact 1
30
Common access referenceOptAlphanumeric1/1AtMax 1
40
Status of the transferOptAtMax 1